WU-OPS-003: Build an Industrial Sensor CSV Validator

Build a standard-library Python tool detecting out-of-order timestamps, stale readings, invalid data, duplicate sensors and quality faults. Human-reviewed, free entry, no cash prize.

WU-OPS-003 · Public free challenge · Human-reviewed · No cash prize

Build an offline Python 3.12 industrial sensor CSV validator. Plant telemetry may include stale values, duplicate timestamps, invalid quality codes and out-of-order sensor events. Your tool should detect these data-quality problems without accessing operational DCS/SCADA equipment.

Input and output contract

  • Read UTF-8 CSV with header timestamp_utc,sensor_id,value,unit,quality; timestamps are RFC3339 UTC ending in Z, with second precision.
  • Read a JSON policy keyed by sensor ID containing unit, min, max and max_gap_seconds. Document the policy schema.
  • Emit JSON with integer row_count (data rows) and issues. Each issue has row (header counts as row 1), severity, code and message.
  • Detect INVALID_TIMESTAMP, UNKNOWN_SENSOR, INVALID_VALUE, OUT_OF_RANGE, UNIT_MISMATCH, DUPLICATE_TIMESTAMP, OUT_OF_ORDER, STALE_GAP and BAD_QUALITY.
  • Recognize GOOD, BAD and UNCERTAIN qualities. Flag BAD and UNCERTAIN as warnings and reject unknown quality strings. Track ordering, duplicates and gaps independently per sensor.
  • Python standard library only, no network calls or control outputs. Explain inclusive limits, malformed rows and deterministic output order.

Public test data

Example policy: {"TT101":{"unit":"C","min":0,"max":120,"max_gap_seconds":120},"PT102":{"unit":"bar","min":0,"max":25,"max_gap_seconds":120}}

timestamp_utc,sensor_id,value,unit,quality
2026-11-01T00:00:00Z,TT101,35,C,GOOD
2026-11-01T00:01:00Z,PT102,8,bar,GOOD
2026-11-01T00:03:30Z,TT101,140,C,GOOD
2026-11-01T00:03:30Z,TT101,36,C,UNCERTAIN
2026-11-01T00:02:00Z,PT102,9,psi,BAD
2026-11-01T00:01:30Z,TT101,37,C,GOOD

Minimum expected findings: row 4 TT101 out of range and gap over 120 seconds; row 5 duplicate TT101 timestamp and uncertain quality; row 6 PT102 unit mismatch and bad quality; row 7 TT101 timestamp out of order. Additional justified reports are allowed.

Rubric — 100 points

  • 60: correct issue codes and row-level reporting.
  • 20: robust quoted CSV and timestamp parsing, per-sensor state and boundary handling.
  • 10: reproducible standard-library-only tests and one-line command.
  • 10: README, assumptions, limitations and safe error handling.

Submit your solution

Submit a public repository URL, 40-hex commit SHA, exact run command and sample output via Arena Submit. A human reviews evidence; no WordPress code execution, paid entry, prize or automatic payout. Do not use confidential plant data or present this tool as a safety interlock. Publication requires entrant consent and reviewer confirmation. Read rules and privacy.


Discover more from WireUnwired Research

Subscribe to get the latest posts sent to your email.